We have designed this clip-on temperature sensor for use with refrigerant lines and copper tubing in hydronics applications. The sensor installs easily without drilling and reacts to temperature changes in seconds. Industry standard sensor elements are compatible with all major controls systems.
Bacnet Room Setpoint & Temp Display can be used in environment monitoring and controlling in industrial,commercial and other buildings,Modbus RS485/Bacnet MS/TP for direct digital reading on all models.
This Probe Temperature Sensor comes standard with a 15mm Stainless Steel Temperature Sensor. This sensor is a 10K Thermistor, with an industry standard Type 2 curve.Connected to the end of the Sensor is 2 UL2468 26/2CAWG 105°C Black Wires with tinned ends.
The duct sensor is used to measure the supply and return air temperature in HVAC system. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. There is a precision thermistor. The probes are epoxy sealed to prevent moisture from migrating into the probe. Field calibration is not generally required. The standard probe length is 12 inch. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement.
This sensor is used to measure water temperature of heated or chilled water and other liquids found in the various mechanical systems of building. The sensor is especially intended for strapping to the outside of a pipe when there is no opportunity to install a well such as in a retrofit or additions to an existing system.The strap on probe is useful in applications such as monitoring batteries, transformers, generators, and generally any place where a complete assembly can not be mounted,Ice rink slabs and soil temperature are other applications.
This sensor is used to measure the supply and return temperature in HVAC system. The flange mount design makes it easy to install the sensor in tight quarters. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. The probe in the photo is our standard model which is always in stock, it has a 8″ probe and a 120″ cable, and employs either a precision thermistor or platinum film sensor, so field calibration is not required. The 10ft(3m) cable is “Plenum Rated”.
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.