The room sensors are used to provide reliable, accurate temperature readings in surface-mount room environments, Energy Management Control Systems, compatible with all the leading control systems.They feature a standard plastic ventilated enclosure.
Product Highlights:
Three low cost room temperature sensors to choose from.
High precision thermistor or RTD, accurate to 0.2C(+/-.36F).
This sensor is used to measure water temperature of heated or chilled water and other liquids in mechanical systems. The sensor is called an immersion type where the sensor is mounted in a brass or stainless steel thermowell which allows the probe to be removed from the pipe without draining the system and protects the probe.There are four thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
This sensor is used to measure the supply and return temperature in HVAC system. The flange mount design makes it easy to install the sensor in tight quarters. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. The probe in the photo is our standard model which is always in stock, it has a 8″ probe and a 120″ cable, and employs either a precision thermistor or platinum film sensor, so field calibration is not required. The 10ft(3m) cable is “Plenum Rated”.
The duct sensor is used to measure the supply and return air temperature in HVAC system. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. There is a precision thermistor. The probes are epoxy sealed to prevent moisture from migrating into the probe. Field calibration is not generally required. The standard probe length is 12 inch. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well.
The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement.
This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start/stop, and supply temperature reset. The housing is made from PVC and stainless steel fittings which shield the probe from direct sunlight. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems.
The Boiler stack temperature sensor and thermowell are designed to monitor the temperature of boiler stacks, steam lines and other applications where the temperature is above the operating range of typical HVAC thermistor type sensors. Maximum operating temperature of 300 Deg C (570 DegF).
The sensor measures temperature in stratified air such as the mixing sections of air handlers. The sensor has a standard 10k type 2 temperature-resistance curve compatible with all major control systems.